Article Data

  • Views 1843
  • Dowloads 150

Original Research

Open Access

Comparıng pulse pressure varıatıon and pleth varıabılıty ındex in the semı-recumbent and trendelenburg posıtıon ın crıtıcally ıll septıc patıents

  • SELMAN KARADAYI 1
  • BEYHAN KARAMANLIOGLU1
  • DILEK MEMIŞ1
  • MEHMET TURAN INAL1
  • F. NESRIN TURAN2

1Department of Anesthesiology, Trakya Univ. Medical Faculty

2 Department of Biostatistics, Trakya Univ. Medical Faculty

DOI: 10.22514/SV132.112017.14 Vol.13,Issue 2,November 2017 pp.91-96

Published: 06 November 2017

*Corresponding Author(s): MEHMET TURAN INAL E-mail: mehmetturaninal@yahoo.com

Abstract

Introduction. Dynamic tests for predict-ing fluid responsiveness have generated increased interest in recent years. One of these tests, pulse pressure variation (PPV), is a parameter calculated from respiratory variations of pulse pressure. Another test, pleth variability index (PVI), is based on respiratory variations of the perfusion in-dex and can be measured non-invasively by pulse oximeter. Previous studies have shown that both tests are valuable in deter-mining fluid responsiveness.

Methods. In this observational prospective study, our aim was to compare the PVI and PPV in order to identify a convenient tool for determining fluid responsiveness. Our study was performed in a surgical and re-animation intensive care unit. We enrolled one hundred mechanically ventilated adult patients diagnosed with sepsis. Exclusion criteria included brain death, spontane-ous breathing, cardiac arrhythmia, and impaired peripheral circulation. We meas-ured the PPV by arterial monitorization and the PVI by using Masimo Radical 7 in the 45° semi-recumbent position (SP) and then 15° Trendelenbug position (TP). We performed correlation and ROC analysis using a >13% fluid responsiveness cut-off value for the PPV and >14% for the PVI. Results. Between the SP and the TP, we did not observe significant decreases in PPV (from 14.17 ± 10.57 to 12.66 ± 9.64; p > 0.05), while we did observe significant de-creases in PVI (from 21.91 ± 13.99 to 20.46 ± 14.12; p < 0.05). The PPV fluid respon-siveness cut-off value in the SP and TP was 20% (78.95% sensitivity, 77.05% specific-ity) and 18% (76.67% sensitivity, 72.46% specificity), respectively. The PVI fluid responsiveness cut-off value in the SP and TP was 20% (80.49% sensitivity, 81.03% specificity) and 16% (81.25% sensitivity, 62.69% specificity), respectively. The area under the ROC of the PPV and PVI was 0.843 and 0.858 in the SP, respectively, and 0.760 and 0.747 in the TP, respectively. The PPV and PVI were correlated in the SP (r = 0.578; p = 0.001) and the TP (r = 0.517; p = 0.001).

Conclusions. Our results showed that the PPV and PVI were correlated independent of position change in sepsis patients. Both tests appear to be equivalently reliable. However, the ability of the PPV and PVI to predict fluid responsiveness decreased in the TP in our study.

Keywords

pulse pressure variation, pleth variability index, fluid responsiveness, sepsis

Cite and Share

SELMAN KARADAYI ,BEYHAN KARAMANLIOGLU,DILEK MEMIŞ,MEHMET TURAN INAL,F. NESRIN TURAN. Comparıng pulse pressure varıatıon and pleth varıabılıty ındex in the semı-recumbent and trendelenburg posıtıon ın crıtıcally ıll septıc patıents. Signa Vitae. 2017. 13(2);91-96.

References

1. Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, et al. Surviving Sepsis Campaign Guidelines Committee includ-ing The Pediatric Subgroup. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med 2013;39(2):165-228.

2. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 2011;39:259-65.

3. Guerin L, Monnet X, Teboul JL. Monitoring volume and fluid responsiveness: from static to dynamic indicators. Best Pract Res Clin Anaesthesiol 2013;27:177-85.

4. Monnet X, Teboul JL. Invasive measures of left ventricular preload. Curr Opin Crit Care 2006;12:235-40.

5. Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001;119:867-73.

6. Biais M, Cottenceau V, Petit L, Masson F, Cochard JF, Sztark F. Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients. Crit Care 2011;15:R168.

7. Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000;162:134-8.

8. Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, et al. Pleth variability index to monitor the respiratory vari-ations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth 2008;101:200-6.

9. Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002;121:2000-8.

10. Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemody-namic response to volume challenge. Crit Care Med 2007;35:64-8.

11. Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000;162:134-8.

12. Feissel M, Badie J, Merlani PG, Faller JP, Bendjelid K. Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients. Crit Care Med 2005;33:2534-9.

13. Vieillard-Baron A, Prin S, Chergui K, Dubourg O, Jardin F. Hemodynamic instability in sepsis: bedside assessment by Doppler echo-cardiography. Am J Respir Crit Care Med 2003; 168:1270.

14. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, et al. Passive leg raising predicts fluid responsiveness in the criti-cally ill. Crit Care Med 2006;34:1402-7.

15. Auler JO Jr, Galas F, Hajjar L, Santos L, Carvalho T, Michard F. Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery. Anesth Analg 2008;106:1201-6

16. Yazigi A, Khoury E, Hlais S, Madi-Jebara S, Haddad F, Hayek G, et al. Pulse pressure variation predicts fluid responsiveness in elderly patients after coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 2012;26:387-90.

17. Zimmermann M, Feibicke T, Keyl C, Prasser C, Moritz S, Graf BM, et al. Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery. Eur J Anaesthesiol 2010;27:555-61.

18. Vos JJ, Kalmar AF, Struys MM, Wietasch JK, Hendriks HG, Scheeren TW. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection. Br J Anaesth 2013;110:940-6.

19. Siswojo AS, Wong DM, Phan TD, Kluger R. Pleth variability index predicts fluid responsiveness in mechanically ventilated adults during general anesthesia for noncardiac surgery. J Cardiothorac Vasc Anesth 2014;28:1505-9.

20. Keller G, Cassar E, Desebbe O, Lehot JJ, Cannesson M. Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers. Crit Care 2008;12:R37.

21. Feissel M, Teboul JL, Merlani P, Badie J, Faller JP, Bendjelid K. Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med 2007;33:993-9.

22. Loupec T, Nanadoumgar H, Frasca D, Petitpas F, Laksiri L, Baudouin D, et al. Pleth variability index predicts fluid responsiveness in critically ill patients. Crit Care Med 2011;39:294-9.

23. Monnet X, Guérin L, Jozwiak M, Bataille A, Julien F, Richard C, et al. Pleth variability index is a weak predictor of fluid responsive-ness in patients receiving norepinephrine. Br J Anaesth 2013;110:207-13.

24. Shelley KH, Jablonka DH, Awad AA, Stout RG, Rezkanna H, Silverman DG. What is the best site for measuring the effect of ventila-tion on the pulse oximeter waveform? Anesth Analg 2006;103:372-7.

25. Hood JA, Wilson RJ. Pleth variability index to predict fluid responsiveness in colorectal surgery. Anesth Analg 2011;113:1058-63.

26. Cannesson M, Delannoy B, Morand A, Rosamel P, Attof Y, Bastien O, et al. Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? Anesth Analg 2008;106:1189-94.

Abstracted / indexed in

Science Citation Index Expanded (SciSearch) Created as SCI in 1964, Science Citation Index Expanded now indexes over 9,200 of the world’s most impactful journals across 178 scientific disciplines. More than 53 million records and 1.18 billion cited references date back from 1900 to present.

Journal Citation Reports/Science Edition Journal Citation Reports/Science Edition aims to evaluate a journal’s value from multiple perspectives including the journal impact factor, descriptive data about a journal’s open access content as well as contributing authors, and provide readers a transparent and publisher-neutral data & statistics information about the journal.

Chemical Abstracts Service Source Index The CAS Source Index (CASSI) Search Tool is an online resource that can quickly identify or confirm journal titles and abbreviations for publications indexed by CAS since 1907, including serial and non-serial scientific and technical publications.

Index Copernicus The Index Copernicus International (ICI) Journals database’s is an international indexation database of scientific journals. It covered international scientific journals which divided into general information, contents of individual issues, detailed bibliography (references) sections for every publication, as well as full texts of publications in the form of attached files (optional). For now, there are more than 58,000 scientific journals registered at ICI.

Geneva Foundation for Medical Education and Research The Geneva Foundation for Medical Education and Research (GFMER) is a non-profit organization established in 2002 and it works in close collaboration with the World Health Organization (WHO). The overall objectives of the Foundation are to promote and develop health education and research programs.

Scopus: CiteScore 1.0 (2022) Scopus is Elsevier's abstract and citation database launched in 2004. Scopus covers nearly 36,377 titles (22,794 active titles and 13,583 Inactive titles) from approximately 11,678 publishers, of which 34,346 are peer-reviewed journals in top-level subject fields: life sciences, social sciences, physical sciences and health sciences.

Embase Embase (often styled EMBASE for Excerpta Medica dataBASE), produced by Elsevier, is a biomedical and pharmacological database of published literature designed to support information managers and pharmacovigilance in complying with the regulatory requirements of a licensed drug.

Submission Turnaround Time

Conferences

Top